EXD COMBINED ALARM SOUNDERS AND FLASHING BEACONS

BEXCS110-05/BEXDCS110-05 ALARM HORN & XENON STROBE

The flameproof BExCS110-05 combination alarm horn sounders and Xenon strobe beacons are suitable for Zone 1 & Zone 2 applications and the BExDCS110-05 versions also for Zone 21 & 22.

Sound level ouputs are up to 117dB(A) at 1 metre with a choice of 32 alarm tones and 3 remotely selectable stages. Sounder & beacon may be connected from a single supply for simultaneous operation or from separate supplies for independent operation.

BExCS110-05/BExDCS110-05 Alarm Horn & Xenon Strobe
Specifications
Sounder/Horn
Maximum Output 117dB (A) @ 1 meter [108dB(A) @ 10ft/3m]
Nominal Output 110dB (A) @ 1m+/-3dB-Tone 2 [101dB (A) @ 10ft/3m]
No. of Tones 32 (UKOOA/PFEER compliant)
No. of Stages 3
Volume Control Max. 110dB (A); Min. 72dB(A)- Tone 2
Effective Range 100m/328ft @ 1KHz
Voltages DC 12vdc; 24vdc; 48vdc
Voltages AC: 115vac; 230vac
Stage Switching Negative or Positive
Beacon
Energy 5 Joules (5Ws)
Flash Rates 1Hz (60fpm)
Peak Candela 500,000 cd-calculated from energy (J)
Effective Intensity 250 cd- calculated from energy (J)
Peak Candela 34,812 cd*- measured ref. to I.E.S.
Effective Intensity 105 cd*-measured ref. to I.E.S.
Lens Colors Amber, Blue, Clear, Green, Red & Yellow
Tube Life: Emissions are reduced to 70% after 8 million flashes
Hazardous Area Rating BExCS11005D ATEX/IECEc
II 2G Ex d IIB T4 Ta -50 to +70C
GOST-R
IExdIIIBT4 Ta -50 to +55C
Hazardous Area Rating BExDCS11005D ATEX/IECEx
II 2G Ex d IIB T4 Ta -50 to +70C
II 2D Ex tD A21 IP67 T115 C
Based on max Ta of +70C
GOST-R
1ExdIIIBT4 Ta -50 to +55C
DIP A21 Ta T5

BEXCS110-L1/BEXDCS110-L1 ALARM HORN & LED

The BExCS110-L1 features sound level outputs of up to 117dB(A) at 1 metre with a choice of 32 alarm tones and 3 remotely selectable stages. The beacon contains an array of 32 high output, multi-function L.E.D.s. with a total of 9 modes of operation – 4 rotating effect modes, 4 flashing modes and a steady mode for use in indicator / status applications. Based on the mode selected the user can also select two alternative L.E.D. modes remotely.

BExCS110-L1/BExDCS110-L1 Alarm Horn & LED
Specifications
Sounder/Horn
Maximum Output 117dB (A) @ 1 meter [108dB(A) @ 10ft/3m]
Nominal Output 110dB (A) @ 1m+/-3dB-Tone 2 [101dB (A) @ 10ft/3m]
No. of Tones 32 (UKOOA/PFEER compliant)
No. of Stages 3
Volume Control Max. 110dB (A); Min. 72dB(A)- Tone 2
Effective Range 100m/328ft @ 1KHz
Voltages DC 12vdc; 24vdc; 48vdc
Voltages AC: 115vac; 230vac
Stage Switching Negative or Positive
L.E.D. Beacon
Light Source Array of 32 hight output L.E.D.s
Effective Candela 11cd*- measured ref. to I.E.S.
Lens Colors Amber, Blue, Green, Red & Yellow
Voltages DC 10-50V dc
Voltages AC: 15V ac: 230V ac
Hazardous Area Rating BExCS11005D ATEX/IECEc
II 2G Ex d IIB T4 Ta -50 to +70C
GOST-R
IExdIIIBT4 Ta -50 to +55C
Hazardous Area Rating BExDCS11005D ATEX/IECEx
II 2G Ex d IIB T4 Ta -50 to +70C
II 2D Ex tD A21 IP67 T115 C
Based on max Ta of +70C
GOST-R
1ExdIIIBT4 Ta -50 to +55C
DIP A21 Ta T5