Exloc Instruments corporate logo
Exloc Instruments: your one-stop-shop for instruments and electrical equipment for use in hazardous classified locations.
Saving you time & money solving challenging problems!
Extronics Uninterruptible Power Supplies
Provide Back Up Power in Hazardous Areas and Extreme Environments
Photo of the Extronics iUPS101 uninterruptible power supply for use in Zone 1 hazardous areas
The iUPS Series provide reliable UPS under extreme conditions including hazardous (classified) locations typically found in chemical plants, oil refineries, and around oil & gas platforms. Critical equipment such as servers, process analysers, and control systems can be protected in the event of a brown out or other supply disturbance.

In Zone 1 the iUPS101 can provide 120 or 230 VAC at 3 kVA for 35 minutes and has alarm and status LEDs visible through a glass window. Surface mounted switches provide input / output power isolation, and a stainless steel close-coupled termination enclosure and external battery box means that the main exlosion proof enclosure does not need to be opened. A second battery box can be added to double the run time. An upgraded version of the original iUPS100.

For Zone 2 the iUPS200 provides 12 or 24VDC at 70W for 120 minutes. The stainless steel enclosure may be wall or pole mounted and also accomodates the battery. Optional features include a choice of built-in status indication and pushbutton control, or active logic outputs for monitoring by a DCS or other control system.

Both models include advanced battery charging technology including temperature compensation to maximize battery life and performance.

Zone 1
iUPS101
with external battery box
Mark of certification to the ATEX Directive
Photo of the Extronics iUPS200 uninterruptible power supply for use in Zone 2 hazardous areas
Zone 2
iUPS200
has internal battery
Model Choice by Zone
iUPS101 for Zone 1
iUPS200 for Zone 2
Certification

ATEX II 2 GD Ex d[e] e IIB T5 Gb

ATEX II 3 G Ex nA II T4 (-20°C≤Ta≤+55°C)
Input Power
200-265VAC, 45-65Hz (120VAC optional)
90-264VAC
Output Power
230VAC ±2%, 50-60Hz at up to 3kVA
(reduces to 220VAC ±2% at high loads)
67.2W, 5.6A at 12VDC, or 62.4W, 2.6A at 24VDC
depending on battery/power output voltage ordered
Backup Time
Approx. 35 minutes at 68°F/20°C, full load.
Can be doubled with second battery.
See data sheet for run time table.
Approx. 120 minutes at 77°F/25°C, full load
Alarm Output
Programmable volt-free contact
Optional logic signals
Environmental
Protection
Main Ex d enclosure: IP66, aluminum alloy
Termination Ex e enclosure: IP66, stainless steel
Battery Ex e enclosure: IP45, stainless steel
IP66, 316L stainless steel
Operating Temperature
-4°F to +131°F / -20°C to +55°C @ 500VA
See data sheet for de-rating table.
-4°F to +131°F / -20°C to +55°C
Weight
Main enclosure + Terminal enclosure: 198lb / 90Kg
Battery enclosure: 269lb / 122Kg
Approx: 33lb / 15Kg
Data Sheets, Manuals, Quotations:


You may also be interested in these related products:
purge & pressurization controlswireless access points RFID tags & readerssolenoid valves

legal noticesite map