Exloc Instruments Logo
Search
Close this search box.

D1xC1X05R 110dB(A) Radial Alarm & 5J Xenon Strobe

GET A QUOTE – Not available for purchase online. Please click the link to request a quote or call 281-978-2040.

The D1xC1X05R is a globally certified alarm horn sounder with a compact, omni-directional horn and combined with a 5 Joule Xenon strobe beacon. The robust Type 4/4X, IP66 marine grade, corrosion proof aluminum enclosure is approved for Class I & II Div 1, Zone 1 & 20, IECEx and ATEx 1, 2, 21 & 22 explosion proof signaling applications.

Featuring 64 alarm tone sounds, each of the available 4 stage/channels can be remotely triggered. Class D amplification provides a high sound output at optimum operating current. The threaded flameproof joint, multiple cable entries and duplicated, pluggable termination simplifies both installation and routine maintenance. The 24Vdc Class I version is approved for public (alarm horn) and private mode fire alarm use (strobe beacon).

 

We are an authorized E2S distributor shipping to locations worldwide.

Connect with Hazardous Area Expert

Questions
or Volume Pricing?

Connect with Hazardous Area Expert:
281-978-2040 | Chat with Us
Get Quote

Description

  • Maximum sound pressure level output of 110dB(A)
  • Automatic synchronization on multi-beacon & sounder systems
  • UL464 / CAN/ULC-S525 & UL1638 / CAN/ULC-S526

Technical Data

Alarm Horn:
Maximum output: 110dB(A) @ 1 meter [101dB(A) @ 10ft/3m]
Class II version: 94dB(A) @ 1 meter [85dB(A) @ 10ft/3m]
Nominal output: 105dB(A) @ 1m +/- 3dB – Tone 4 [96dB(A) @ 10ft/3m]
Class II version: 90dB(A) @ 1 metre [81dB(A) @ 10ft/3m]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Full range
Effective range: 125m/410ft @ 1KHz
Voltages DC: 24Vdc (20-28Vdc)
Voltages AC: 110-120Vac, 220-240Vac
Stage switching: DC units: negative or positive
AC units: common supply line
Strobe Beacon:
Energy: 5 Joules (5Ws)
Flash rates: Option 1: 1Hz (60 fpm)
Option 2: 1.5Hz (90 fpm)
Option 3: Double Strike
Eff. Intensity: 143 cd* – measured ref. to I.E.S.
Peak Candela: 46,976 cd* – measured ref. to I.E.S.
Eff. Intensity: 250 cd – calculated from energy (J)
Peak Candela: 500,000 cd – calculated from energy (J)
Lens colors: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Tube life: Emissions reduced to 70% > 5 million flashes
General:
Ingress protection: EN60529: IP66
UL50E / NEMA250: 4 / 4X / 3R / 13
Enclosure material: Marine grade aluminum LM6 – copper free
Chromated & powder coated – corrosion proof
Enclosure color: Red or Grey, custom colors available on request
Cable entries: 1×1/2″NPT & 2xM20 – thread adaptors available
Terminals: 0.5 – 2.5mm² (20-14 AWG) Pluggable, duplicated terminals
Grounding stud: M5
Line monitoring: Blocking diode included. EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor or diode (DC versions) can be fitted
Enclosure volume: <2 liters
Installation temp: -55 to +85°C [-67° to +185°F]
Storage temp: -55 to +85°C [-67° to +185°F]
Relative humidity: 99%
Vibration test: 35Hz for a duration 4Hr (UL464)
Jarring test: 3ft/lb Energy (UL464)
Impact test: 3x 5lb (UL464)
Relative humidity: 95% – Additional topicalization is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight: 4.9kg/10.9lbs

Approvals

  • UL/cUL/ULC File ref: E230764
  • IECEx Certificate: IECEx ULD 19.0008X
  • ATEX Certificate: DEMKO 19 ATEX 2141X
  • CSFM listing: 7136-2279:0506
  • UKCA certificate: UL21UKEX2132X

Coding

  • NEC Class / Zone
    Class I Zone 1 IIC T4 Gb Ta -55°C to +85°C
    Class I Zone 1 IIC T4A Gb Ta -55°C to +80°C
    Class I Zone 1 IIC T5 Gb Ta -55°C to +60°C
    Class I Zone 1 IIC T6 Gb Ta -55°C to +45°C
  • CEC Class / Zone
    Class I Zone 1 IIC T5 Gb Ta -55°C to +55°C
    Class I Zone 1 IIC T6 Gb Ta -55°C to +45°C
  • NEC Class / Div
    Class I Div 1 ABCD T4 Ta -55°C to +85°C
    Class I Div 1 ABCD T4A Ta -55°C to +80°C
    Class I Div 1 ABCD T5 Ta -55°C to +60°C
    Class I Div 1 ABCD T6 Ta -55°C to +45°C
  • CEC Class / Div
    Class I Div 1 ABCD T5 Ta -55°C to +55°C
    Class I Div 1 ABCD T6 Ta -55°C to +45°C
  • IECEx / ATEX
    II 2G Ex db IIC T4/T5 Gb Ta -55°C to +75°C
    II 2G Ex db IIC T5 Gb Ta -55°C to +55°C
    II 2G Ex db IIC T6 Gb Ta -55°C to +40°C (DC only)
    II 2D Ex tb IIIC T115°C Db Ta ‐55°C to +75°C
  • NEC Class / Zone – Product version: D
    Class II Zone 20 IIIB T4A Gb Ta -55°C to +70°C
  • NEC Class / Div – Product version: D
    Class II Div 1 Group FG T4A Ta -55°C to +70°C
    See product manual for full voltage specific coding.

Resources

Video

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT

Download Product and Service Catalogs

Fill out your contact details and we will forward you to download our product brochures. 

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT