TACHOMETERS

  • Separate easy to read speed and run-time displays
  • Rugged enclosures, including Stainless
  • Steel panel mounting instrument.
  • Field and panel mounting models
  • Will function with wide range of sensors
  • Isolated synchronous pulse output option on small panel models
  • Certifications:
    -Intrinsically safe for Class I, Division 1, Groups A, B, C, D
    -Intrinsically safe for Class II, Division 1, Groups E, F, G
    -Intrinsically safe for Class III, Division 1
    -Intrinsically safe Ex ia for Zones 0, 1, 2, 20, 21, & 22
    -Rugged Stainless Steel Ex ia model may be installed in certified Ex e, Ex p or Ex t panel enclosure without invalidating the enclosure’s certification.
    -Nonincendive Class I, Division 2, Groups A, B, C, D
    -Nonincendive Class II, Division 2, Groups F, G
    -Nonincendive Class III, Division 2
    -Ex nA & Ex tc for Zone 2 & 22 applications
    -General purpose for use in safe area
  • Accessories:
    -Backlight
    -Isolated dual alarms
    -Isolated 4/20mA output
    -Pipe mounting kits
    -Rear IP66 Sealing Kit for Panel Mounting Models
    -Scale Card and Tag – preprinted at no charge if ordered with tachometer
  • Three year guarantee

This range of tachometers can display speed in engineering units from almost any pulse output sensor such as a proximity detector. To simplify maintenance they can also display the run-time of the monitored machinery. Parameters are easy to adjust on-site and models are available for installation in most safe and hazardous areas. Instruments can be supplied ready to install with customer specified configuration, scale and tag marking.

Tachometers, Intrinsically safe, field mounting and panel mounting

These easy to use, intrinsically safe tachometers can display speed in engineering units from a wide variety of pulse output sensors such as a proximity detector or switch contact. To simplify maintenance, the instruments also contain a second display which can simultaneously show the run-time of the monitored machinery. International certification allows worldwide installation.

Accessories, include a display backlight, isolated dual alarms and an isolated 4/20mA output.

Tachometers can be supplied configured and fitted with a customer specified printed scale card showing the units of measurement for no additional charge. An optional Stainless Steel legend plate is also available which can be supplied laser engraved with customer specified tag and application information for field mount models.

Intrinsically Safe field mounting Intrinsically Safe field mounting Intrinsically Safe panel mounting Intrinsically Safe panel mounting Intrinsically Safe panel mounting
Model BA314E BA314G BA317E BA318E BA317E-SS
Image
Mounting Type Field Field Compact Panel Panel Rugged panel
Enclosure 141 x 212 mm 122 x 120 mm 96 x 48 mm 105 x 60 mm
Separate terminal
compartment
Yes No N/A
Case material GRP Noryl 316 Stainless Steel
Protection IP66 Front IP66, rear IP20
Display Speed: 8 digits 18mm high
Run-time: 6 digits 12mm high
Speed:
8 digits 9mm high
Run-time:
6 digits 6mm high
Speed:
8 digits 18mm high
Run-time:
6 digits 12mm high
Speed:
8 digits 9mm high
Run-time:
6 digits 6mm high
Certification
Europe
ATEX
Group II Category 1G
Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Group II Category 1GD
Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C
Group II Category 1G
Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +70°C
Group II Category 1GD
Ex ia IIC T5 Ga
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C
USA & Canada
ETL & cETL
Intrinsic safety
Class I Div 1 Gp A, B, C, D T5 (USA & Canada)
Class II Div 1 Gp E, F, G. Class III Div 1 (USA & Canada)
Class I Zone 0 AEx ia IIC T5 Ga (USA)
Ex ia IIC T5 Ga (Canada)
-40°C ≤ Ta ≤ 70°C
Class I Div 1 Gp A, B, C, D T5 (USA & Canada)
Class II Div 1 Gp E, F, G.
Class III Div 1 (USA & Canada)
Class I Zone 0 AEx ia IIC T5 Ga (USA)
Ex ia IIC T5 Ga (Canada)
-40°C ≤ Ta ≤ 70°C
Class I Div 1 Gp A, B, C, D T5 (USA & Canada) Class II Div 1 Gp E, F, G.

Class III Div 1 (USA & Canada)

Class I Zone 0 AEx ia IIC T5 Ga (USA)

Zone 20 AEx ia IIIC T80°C Da (USA) Ex ia IIIC T80°C Da (Canada) -40°C ≤ Ta ≤ 60°C

May be installed in an AEx e, AEx p, AEx n or AEx t panel enclosure without invalidating enclosure certification.
USA & Canada
ETL & cETL
Nonincendive
Class I Div 2 Gp A, B, C, D T5
Class II Div 2 Gp F, G. Class III Div 2
-40°C ≤ Ta ≤ 70°C
Class I Div 2 Gp A, B, C, D T5 (USA & Canada)
Class II Div 2 Gp F, G. Class III Div 2 (USA & Canada)
-40°C ≤ Ta ≤ 70°C
International
IECEx
Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C
Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +70°C Ex ia IIC T5 Ga
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C
Optional
Backlight Included Yes Yes
Alarms Included Yes Yes* Yes Yes*
4/20mA output Included Yes Yes* Yes Yes*
Pulse output N/A Yes* Standard Yes*

# Shown with optional separately powered backlight.
* Only one output option can be fitted.

Tachometers, Nonincendive and Ex nA, field mounting and panel mounting

These easy to use, nonincendive and Ex nA and Ex tc certified tachometers can display speed in engineering units from a wide variety of pulse output
sensors such as a proximity detector or switch contact.It can be installed in Class I, Division 2 and Class II, Division 2, Zone 2 or 22 without the need for
Zener barriers or galvanic isolators thus significantly reducing cost. International certification allows use worldwide.

To simplify maintenance, the instruments also contain a second display which can simultaneously show the run-time of the monitored machinery.

Accessories, include a display backlight, isolated dual alarms and/or isolated synchronous pulse output and/or isolated 4/20mA output.

The instrument can be supplied configured and fitted with a customer specified printed scale card showing the units of measurement for no additional
charge. Specified tag or application infromation can also be printed onto the rear of the instrument. An optional Stainless Steel legend plate is also
available which can be supplied laser engraved with customer specified tag and application information for field mount models.

Non-Incendive field mounting Non-Incendive panel mounting
Model BA314NG BA317NE
Image
Mounting Field Compact Rugged panel
Enclosure 122 x 120 mm 105 x 60 mm
Separate terminal
compartment
N/A
Case material GRP 316 Stainless Steel
Protection IP66 Front IP66, rear IP20
Display Speed:
8 digits 18mm high
Run-time:
6 digits 12mm high
Speed:
8 digits 9mm high
Run-time:
6 digits 6mm high
Certification Ex ic certification codes only refer to the instrument push button contacts which are nonincendive.
Europe
ATEX
Group II Category 3GD
Ex nA ic IIC T5 Gc
Ex ic tc IIIC T80°C Dc
-40°C ≤ Ta ≤ +60°C
USA ETL Class I Zone 2 AEx nA ic IIC T5 Gc
Zone 22 AEx ic tc IIIC T80°C Dc
-40°C ≤ Ta ≤ 60°C
Canada cETL Ex nA ic IIC T5 Gc
Ex n IIC T5 Gc
Ex ic tc IIIC T80°C Dc
Class III Div 2 Class II Div 2 Gp F, G
-40°C ≤ Ta ≤ 60°C
Ex nA ic IIC T5 Gc
Ex n IIC T5 Gc
-40°C ≤ Ta ≤ 60°C
USA & Canada
ETL & cETL
Nonincendive
Included Above
International
IECEx
Ex nA ic IIC T5 Gc
Ex ic tc IIIC T80°C Dc
-40°C ≤ Ta ≤ +60°C
Ex nA ic IIC T5 Gc
Ex ic tc IIIC T80°C Dc IP66
-40°C ≤ Ta ≤ +60°C
Optional
Backlight Yes
Alarms Yes Yes*
4/20mA output Yes Yes*
Pulse output N/A Yes*

# Shown with optional separately powered backlight.
* Only one output option can be fitted.

Tachometers, General Purpose, field mounting and panel mounting

These easy to use, general purpose tachometers can process and display the total number of pulses received and their rate in the same or different
engineering units from a wide variety of sensors such as a proximity detector or switch contact. To simplify maintenance, the instruments also contain
a second display which can simultaneously show the run-time of the monitored machinery.

Accessories, include a display backlight, isolated dual alarms and/or isolated synchronous pulse output and/or isolated 4/20mA output.

Tachometers can be supplied configured and fitted with a customer specified printed scale card showing the units of measurement for no additional
charge. Specified tag or application information can also be printed onto the rear of the instrument. An optional Stainless Steel legend plate is also
available which can be supplied laser engraved with customer specified tag and application information for field mount models.

General Purpose field mounting General Purpose panel mounting General Purpose panel mounting General Purpose panel mounting
Model BA514G BA517E BA518E BA517E-SS
Image
Mounting Field Compact Panel Rugged panel
Enclosure 122 x 120 mm 96 x 48 mm 144 x 72 mm 105 x 60 mm
Separate terminal
compartment
N/A
Case material GRP Noryl 316 Stainless Steel
Protection IP66 Front IP66, rear IP20
Display Speed: 8 digits 18mm high
Run-time: 6 digits 12mm high
Speed:
8 digits 9mm high
Run-time:
6 digits 6mm high
Speed:
8 digits 18mm high
Run-time:
6 digits 12mm high
Speed:
8 digits 9mm high
Run-time:
6 digits 6mm high
Optional
Backlight Yes Yes
Alarms Yes Yes* Yes Yes*
4/20mA output Yes Yes* Yes Yes*
Pulse output N/A Yes* Standard Yes*

# Shown with optional separately powered backlight.
* Only one output option can be fitted.

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT

Download Product and Service Catalogs