GET A QUOTE – Not available for purchase online. Please click the link to request a quote or call 281-801-6534.
This third generation, intrinsically safe BA358E 4/20mA loop powered Rate Totalizer has large high contrast rate and total displays with an extended operating temperature range. It can display flow rate per second, minute or hour and total flow in the same or different units. Adjustable linearization or square root extraction are selectable and the instrument can display and totalize bi-directional flows.
No additional charge is made for factory calibration or for scale card and tag marking, however the Rate Totalizer can easily be recalibrated on-site.
Coated printed circuit boards plus extensive thermal and vibration testing provides maximum reliability supported by a three year guarantee.



Technical Data
Legacy Status | Replaces BA358C | |||
Mounting & Enclosure | Panel 144 x 72 mm | |||
Display Format |
![]() |
|||
Ingress Protection | Front IP66, rear IP20 | |||
Linearizer, 16-segment adjustable linearizer | Included | |||
Square root extractor | Included | |||
Alarm/Control Outputs | Optional | |||
Backlight, which may be loop or separately powered | Optional | |||
External Pushbuttons | Standard | |||
Scalecard and tag/application marking (no charge) | Optional |
Approvals



FM USA and FM Canada |
cFMus, ATEX, IECEx, Inmetro Entity
IS / I / A, B, C, D / T5 Ta = 70°C I / 0 / AEx ia IIC / T5 Ta = 70°C Non-incendive NI / I / 2 / ABCD / T5 Ta = 70°C – NIFW NI / II / 2 / EFG / T5 Ta = 70°C – NIFW NI / III / 2 / T5 Ta = 70°C – NIFW I / 2 / IIC / T5 Ta = 70°C – NIFW |
|||
Europe ATEX |
Gas - Group II Category 1G Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +70°C Dust - Group II Category 1D Ex ia IIIC T80°C Da IP20 -40°C ≤ Ta ≤ +70°C |
|||
International IECEx |
Gas - Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +70°C Dust - Ex ia IIIC T80°C Da IP20 -40°C ≤ Ta ≤ +70°C |