Isolated synchronous pulse output option on small panel models
Models: -One pulse input, externally powered -Two pulse inputs with quadrature sensing decoding -Field and panel mounting
Certifications: -Intrinsically safe for Class I, Division 1, Groups A, B, C, D -Intrinsically safe for Class II, Division 1, Groups E, F, G -Intrinsically safe for Class III, Division 1 -Intrinsically safe Ex ia for Zones 0, 1, 2, 20, 21, & 22 -Rugged Stainless Steel Ex ia model may be installed in certified Ex e, Ex p or Ex t panel enclosure without invalidating the enclosure’s certification. -Nonincendive Class I, Division 2, Groups A, B, C, D -Nonincendive Class II, Division 2, Groups F, G -Nonincendive Class III, Division 2 -Ex nA & Ex tc for Zone 2 & 22 applications -General purpose for use in safe area
Accessories: -Backlight -Isolated dual alarms -Isolated 4/20mA output -Isolated synchronous pulse output on some models -Pipe mounting kits -Rear IP66 Sealing Kit for Panel Mounting Models -Scale Card and Tag – preprinted at no charge if ordered with counter
Three year guarantee
This range of pulse counters includes models with two inputs which can display the sum or difference of the inputs and position from a quadrature encoder. All models display the total number of input pulses and their rate simultaneously in the same or different engineering units. Parameters are easy to adjust on-site allowing these counters to be used with almost any sensor. Instruments can be supplied ready to install with customer specified configuration, scale and tag marking.
Counters, Intrinsically safe, field mounting and panel mounting
These easy to use, intrinsically safe counters can process and simultaneously display the total number of pulses received and their rate in the same or different engineering units from a wide variety of sensors. The two input model can display the sum or difference of the two inputs and can also display position and rate from a quadrature sensor. International certification allows worldwide installation.
Accessories, include a display backlight, isolated dual alarms and an isolated 4/20mA output.
Counters can be supplied configured and fitted with a customer specified printed scale card showing the units of measurement for no additional charge. An optional Stainless Steel legend plate is also available which can be supplied laser engraved with customer specified tag and application information for field mount models.
Intrinsically Safe field mounting
Intrinsically Safe field mounting
Intrinsically Safe panel mounting
Intrinsically Safe panel mounting
Intrinsically Safe panel mounting
Model
BA364E
BA364G
BA367E
BA368E
BA367E-SS
Image
Mounting Type
Field
Field Compact
Panel
Panel
Rugged panel
Enclosure
141 x 212 mm
122 x 120 mm
96 x 48 mm
144 x 72 mm
105 x 60 mm
Separate terminal
compartment
Yes
No
N/A
Case material
GRP
Noryl
316 Stainless Steel
Protection
IP66
Front IP66, rear IP20
Display
8 digits 18mm high
and 6 digits 12mm high
8 digits 9mm high
6 digits 6mm high
8 digits 18mm high
6 digits 12mm high
8 digits 9mm high
6 digits 6mm high
No. of inputs
2
1
2
1
Certification
Europe
ATEX
Group II Category 1G
Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Group II Category 1GD
Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C
Group II Category 1G
Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +70°C
Group II Category 1GD
Ex ia IIC T5 Ga
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C
USA & Canada
ETL & cETL
Intrinsic safety
Class I Div 1 Gp A, B, C, D T5 (USA & Canada)
Class II Div 1 Gp E, F, G. Class III Div 1 (USA & Canada)
Class I Zone 0 AEx ia IIC T5 Ga (USA)
Ex ia IIC T5 Ga (Canada)
-40°C ≤ Ta ≤ 70°C
Class I Div 1 Gp A, B, C, D T5 (USA & Canada)
Class II Div 1 Gp E, F, G.
Class III Div 1 (USA & Canada)
Class I Zone 0 AEx ia IIC T5 Ga (USA)
Ex ia IIC T5 Ga (Canada)
-40°C ≤ Ta ≤ 70°C
Class I Div 1 Gp A, B, C, D T5 (USA & Canada) Class II Div 1 Gp E, F, G.
Class III Div 1 (USA & Canada)
Class I Zone 0 AEx ia IIC T5 Ga (USA)
Zone 20 AEx ia IIIC
T80°C Da (USA)
Ex ia IIIC T80°C Da
(Canada)
-40°C ≤ Ta ≤ 60°C
May be installed in an
AEx e, AEx p, AEx n
or AEx t panel
enclosure without
invalidating enclosure
certification.
USA & Canada
ETL & cETL
Nonincendive
Class I Div 2 Gp A, B, C, D T5
Class II Div 2 Gp F, G. Class III Div 2
-40°C ≤ Ta ≤ 70°C
Class I Div 2 Gp A, B, C, D T5 (USA & Canada)
Class II Div 2 Gp F, G. Class III Div 2 (USA & Canada)
-40°C ≤ Ta ≤ 70°C
International
IECEx
Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C
Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +70°C
Ex ia IIC T5 Ga
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C
Optional
Backlight
Included
Yes
Yes
Alarms
Included
Yes
Yes*
Yes
Yes*
4/20mA output
Included
Yes
Yes*
Yes
Yes*
Pulse output
N/A
Yes*
Standard
Yes*
# Shown with optional separately powered backlight. * Only one output option can be fitted.
Counters, Type nA, field mounting and panel mounting
These easy to use, Ex nA and Ex tc certified counter can process and simultaneously display the total number of pulses received and their rate in the same or different engineering units from a wide variety of sensors. Can be installed in Zone 2 or 22 without the need for Zener barriers or galvanic isolators thus significantly reducing cost. International certification allows use worldwide.
Accessories, include a display backlight, isolated dual alarms and an isolated 4/20mA output.
The instrument can be supplied configured and fitted with a customer specified printed scale card showing the units of measurement for no additional charge. An optional Stainless Steel legend plate is also available which can be supplied laser engraved with customer specified tag and application information.
Type nA for field mounting
Type nA for panel mounting
Model
BA364NG
BA367NE
Image
Mouting Type
Field Compact
Rugged Panel
Enclosure
122 x 120 mm
105 x 60 mm
Separate terminal
compartment
N/A
N/A
Case material
GRP
316 Stainless Steel
Protection
IP66
Front IP66, rear IP20
Display
Primary: 8 digits 18mm high
and 6 digits 12mm high
Primary: 8 digits 9mm high
and 6 digits 6mm high
No. of inputs
2
1
Certification
Ex ic certification codes only refer to the instrument push button contacts which are nonincendive.
Europe
ATEX
Group II Category 3GD
Ex nA ic IIC T5 Gc
Ex ic tc IIIC T80°C Dc
-40°C ≤ Ta ≤ +60°C
USA ETL
Class I Zone 2 AEx nA ic IIC T5 Gc
Zone 22 AEx ic tc IIIC T80°C Dc
-40°C ≤ Ta ≤ 60°C
Canada cETL
Ex nA ic IIC T5 Gc
Ex n IIC T5 Gc
Ex ic tc IIIC T80°C Dc
Class III Div 2 Class II Div 2 Gp F, G
-40°C ≤ Ta ≤ 60°C
Ex nA ic IIC T5 Gc
Ex n IIC T5 Gc
-40°C ≤ Ta ≤ 60°C
USA & Canada
ETL & cETL
Nonincendive
Class I Div 2 Gp A, B, C, D T5 (USA & Canada)
Class II Div 2 Gp F, G. Class III Div 2 (USA & Canada)
-40°C ≤ Ta ≤ 70°C
International
IECEx
Ex nA ic IIC T5 Gc
Ex ic tc IIIC T80°C Dc
-40°C ≤ Ta ≤ +60°C
Ex nA ic IIC T5 Gc
Ex ic tc IIIC T80°C Dc IP66
-40°C ≤ Ta ≤ +60°C
Optional
Backlight
Yes
Alarms
Yes
Yes*
4/20mA output
Yes
Yes*
Pulse output
N/A
Yes*
# Shown with optional separately powered backlight. * Only one output option can be fitted.
Counters, General Purpose, field mounting and panel mounting
These easy to use, general purpose counters can process and simultaneously display the total number of pulses received and their rate in the same or different engineering units from a wide variety of sensors. This two input model can display the sum or difference of the two inputs and can also display position and rate from a quadrature sensor.
Accessories, include a display backlight, isolated dual alarms and/or isolated synchronous pulse output and/or isolated 4/20mA output.
Counters can be supplied configured and fitted with a customer specified printed scale card showing the units of measurement for no additional charge. Specified tag or application information can also be printed onto the rear of the instrument. An optional Stainless Steel legend plate is also available which can be supplied laser engraved with customer specified tag and application information for field mount models.
General Purpose Field Mounting
General Purpose Panel Mounting
General Purpose Panel Mounting
General Purpose panel mounting
Model
BA564G
BA567E
BA568E
BA567E-SS
Image
Mouting Type
Field Compact
Panel
Rugged Panel
Enclosure
122 x 120 mm
96 x 48 mm
144 x 72 mm
105 x 60 mm
Separate terminal
compartment
N/A
Case material
GRP
Noryl
316 Stainless Steel
Protection
IP66
Front IP66, rear IP20
Display
8 digits 18mm high
and 6 digits 12mm high
8 digits 9mm high
6 digits 6mm high
8 digits 18mm high
6 digits 12mm high
8 digits 9mm high
6 digits 6mm high
No. of inputs
2
1
2
1
Optional
Backlight
Yes
Yes
Alarms
Yes
Yes*
Yes
Yes*
4/20mA output
Yes
Yes*
Yes
Yes*
Pulse output
N/A
Yes*
Standard
Yes*