- Description
- Technical Data
- Approvals
- Resources
Description
GET A QUOTE – Not available for purchase online. Please click the link to request a quote or call 281-688-9468.
The BA337E-SS is an intrinsically safe rate totalizer housed in a rugged stainless steel enclosure. The intrinsic safety certification and the rugged enclosure allow the BA337E-SS to be safely installed in an Ex e, Ex p, Ex n or Ex t panel enclosure without invalidating the panel enclosures certification. The intrinsically safe totalizer may also be installed in any uncertified panel enclosure located in Zone 0, 1 or 2 and is particularly suitable for marine environments or where the front of the instrument is likely to be impacted. The rate totalizer is easy to use and can be configured on-site to operate with flowmeters having a wide variety of pulse outputs. A slide-in scale card simplifies identification.
This easy to use, intrinsically safe rate totalizer can process and simultaneously display rate of flow and total flow from the pulse output of most flowmeters. International certification allows worldwide installation and a 16 segment linearizer ensures maximum accuracy.
Rate totalizer can be supplied configured and fitted with a customer specified printed scale card showing the units of measurement for no additional charge. Specified tag or application information can also be printed onto the rear of the instrument.
Supported by a three year guarantee.



Technical Data
Legacy Status | Current | |||
Mounting & Enclosures | Rugged Panel 105 x 60 mm | |||
Case Material | 316 Stainless Steel | |||
Display | Primary: 8 digits, 9 mm high Secondary: 6 digits, 6 mm high |
|||
Ingress Protection | Front IP66, rear IP20 | |||
Alarm/Control Outputs | Optional (or 4 to 20mA Output or Pulse Output) | |||
4 to 20 mA Output | Optional (or Alarm/Control Outputs or Pulse Output) | |||
Backlight | Optional, internally powered | |||
External Pushbuttons | Standard | |||
Isolated Synchronous Pulse Output | Optional (or Alarm/Control Outputs or 4 to 20mA Output) | |||
Scale card & tag/application marking | Optional, when information provided |
Approvals



ATEX |
IECEx |
ETL USA & Canada |